CPU Card - MP1001
Communication Modbus RTU Card with Master/slave Modbus protocol. It manages the following Modbus variables: 512 Input variables, 512 Output variables, 1024 16-bit analogue variables. The values on to 4-20mA analogue cards can be transmitted to the DCS system. Its Output supplies two independent connections, a RS485 Half Duplex and a RS232. The analogue variables boast the engineered values relative to 4-20mA analogue cards.
Communication Card - SC1001
Monitoring Analogue Input Card - IA2001 is just for 4-20mA sensors and detectors as like as Gas Detector and Flame Detector
Analogue Input Card - IA2001
With this input card , all conventional detectors as like as smoke detector, heat detector, multi detector, and manual call points can be monitored and can send signals to f&g control panel .
Digital Input Card - ID1001
Card with 16 controlled Output channels of 500mA for the command of solenoids with safety related functions. It performs testing every 2 seconds on the channels cyclically, in case of discrepancy between the set signal and the read signal, the unit promptly warns about the failure condition. The Output is tested for the following: line opening, short circuit towards positive pole, short circuit towards negative pole, failure of piloting DMOS device, over-temperature of piloting DMOS device, power voltage outside the limits allowed. To increase output current, channels can be connected in parallel.
Digital Output Card - OD3001
Card with 4 controlled Output channels of 2 A for the command of solenoids with safety related functions.. The Output is tested for the following: line opening, short circuit towards positive pole, short circuit towards negative pole, failure of piloting DMOS device, over-temperature of piloting DMOS device, power voltage outside the limits allowed. To increase output current, channels can be connected in parallel.
Digital Output Card - OD3002
Card with 32 open collector, non-controlled Output channels of 250mA. This card effects status and functionality checks, but does not monitor the control channels.
Digital Output Card - OD3005
Addressable Loop Card for devices addressed with Apollo protocol fire alarm . It manages up to 127 devices of max. Two points each.
Addressable Loop Card (Apollo) - LP4001
Addressable Loop Card for devices addressed with ESP protocol(Hochiki)Fire Alarm. It manages up to 254 devices of max. Two points each.
Addressable Loop Card (Hochiki) - LP4002